Fire rated doors that hold the line for 2 hours

Stark Fire doors and shutters from Tata Steel. Factory-engineered, tested to BS 476 Part 22 & 24 (2000), and ready for your safety. Because real access can’t wait.

120 min
Fire resistance
46 min
(thermal insulation)
BS 476
Part 22 & 24 (2000)
1 year
Limited warranty
Red fire-rated door with a push bar

Four jobs a fire door does when it matters

Sometimes, it’s a straightforward job to shut. A fire door controls the fire and smoke, so people get time to leave and fire-fighting can proceed.

Slows the spread of fire

It reduces the propagation of fire and heat, and keeps flames on one side.

Contains smoke

Contains smoke, keeps escape routes clear and allows fire-fighting to work.

Gives a clear way out

Provides a safe route for people to evacuate quickly and safely.

Works as an everyday door

Adds daily security and is used as a normal door.

Why India’s buildings need them

From residential (apartments, hotels, PGs) to commercial (offices, hospitals, schools) and industrial (factories, warehouses), fire safety is a must.

Choose your door

Fire rated doors

For staircases, corridors, plant rooms and exits. Single or double leaf, with options of vision panel and panic bar.

Shaft / duct access doors

Smaller doors for electrical ducts and fire equipment. Available fire rated or non fire rated.

Used in: high-rise buildings, metro stations, hospitals, hotels, malls, multiplexes, power plants, telecom centres, industrial plants, schools, software parks and restaurants.

Built for demanding environments

  • Galvanised or stainless steel
  • Honeycomb, rockwool or mineral wool core
  • 120 minute rating for stability and integrity (BS476)
  • UL, welded doors for 90 minutes
  • Vision panel rated up to 120 minutes
  • Non-fragile finishes to sharp edges
  • Factory prepared for mortise hardware
  • Fully flush construction
  • Fire-rated flush wall openings and dry wall partitions
  • Wide range of colours, wood grain finish options
  • Tested up to 650°C
  • Installed by trained, skilled installation teams

Technical specifications

Fire rated doors & door rating.

Door leaf1.2 mm (18 SWG) or 0.8 mm (22 SWG) light-gauge galvanised steel sheet. 15 / 27 mm thick, 44 mm overall.
InfillRockwool, mineral wool or fire-retardant honeycomb.
Door frame1.6 mm (16 SWG) or 1.2 mm (18 SWG) galvanised steel sheet, IS 277. Single or double rebate. Profile: 143 mm x 56 mm.
Vision glass5 mm clear or wired glass, secured by rubber gasket. 200 mm or 300 mm square; high-integrity rated glass available.
FinishZinc-rich base coating primer. Epoxy polyester or polyurethane powder coat, 60–95 microns.
HingesStainless steel ball-bearing butt hinges, 102 mm x 76 mm x 3 mm (thk). 3 per door, depending on height.
LockMortise sash lock, dead bolt, latch or panic device. Concealed fixings; surface-mounted or concealed door options.
Maximum sizeSingle leaf: 2.15 m (high) x 1.22 m (wide). Double leaf: 2.30 m (high) x 2.44 m (wide).
TestedBS 476 Part 22 & 24 (2000) (Certified) Building Research Institute.

Hardware from trusted makers

Every set includes fire rated hardware tested with the door.

Hinges, panic bars, D-handles

Geze, Haffele, Dorma, Kich

Door closers

Dorgar, Geze, Hettich, Dorma, Assa Abloy, Kich

Main door locks and dead locks

Geze, Haffele, Dorma, Korma, Kich

Checklist before you buy: Fire rated frame, hinges, closer, lock, handle and vision panel, plus manufacturer data and sample test results. Buy the frame with the shutter to both meet fire, smoke and acoustic standards.

Frequently asked questions

Need fire doors for your project?

Tell us the door type, size and quantity. Our team will get back to you with a quote.

Enquire Now